38th Turbomachinery
Symposium
September 14-17, 2009
George R. Brown Convention Center · Houston, Texas
Opportunities
Unparalleled
EARN CEU CREDITS
Solutions-based Case Studies
In-depth Short Courses
Innovative Discussion Groups
Hands-on Tutorials
Pioneering Lectures
Outstanding Exhibit Floor
Exhibits Open Free
to the Public:
3:30 p.m. - 7:00 p.m.
9:30 a.m. - 12:00 p.m.
Co-located with
800/787-2356
Koch Membrane System
978/694-7000
MS
Micronics Filtration
603/433-1299
New Logic Research Inc.
510/655-7305
MS,MD
WF
MS,MD
SC,WQ
RC,WL
MS,MD
Sanborn Technologies
508/660-9150
Smith & Loveless Inc. MS
800/898-9122, www.smithandloveless.com
TriSep Corp.
805/964-8003
HF/PS DF,DW
WB,FC
DS
HF/PP EC,DW
WB,FC
HF/PO,PP DF,DW
PT,PC DS
PS,PV
HF/PV OW
< 9
275 50-250
variable 30-300
15-17 60-70
HF/PV WB,FC
290
HF/PL DS,DW
FC,WB
WR
1-10
0-10
KEY
Equipment/Service
AE A&E Facility Design Services
AP Auxiliary Power & Energy
MD Membrane Systems Design
MS Membrane Systems Installations
RC Related Chemical Systems
SC SCADA/Control System Design
WF Water Facility Operating Services
WL Water Quality Lab & Certification Svcs
WQ Water Quality Analytical Equipment/Sys
NA Not Applicable
Installation
DF Direct Filtration for Potable Water Supplies
DS Desalination Systems
DW Direct Wastewater or Tertiary Filtration
EC Enhanced Coagulation for Potable Water Supplies
FC Food Processing Waste Recoveries
OW Oily Wastewater
WB Wastewater Bioreactor
WR Industrial Wastewater Reuse
Membrane
Device
FP Flat Plate
HF Hollow Fiber
Material
PC Polycarbonate
PL Polyethersulfone
PO Polyamide
PP Polypropylene
PS Polysulfone
PT Polytetrafluoroethylene
PV Polyvinylidenefluoride
For more information
3PONSORED BY 4HE 4URBOMACHINER Y , ABORATOR Y s 4EXAS - 5NIVERSI TY
4!- 5 s #OLLEGE 3 TATION 48
or to join our mail list –
0H s &X
email or call now. INQUIRY TURBO LAB TAMU EDU s H TTP TURBOLAB TAMU EDU
Liquid Polymer Blending Circle 141 on Card
The dynaBLEND™ pre-engineered liquid polymer blending systems feature
diaphragm metering or progressing cavity pumps. The patented hydrody-
namic or mechanical mixing provides polymer activation technology paired
to particular process and flow demands. Control options range from simple
Gas Monitors
Ultima XA, XE and XIR Gas Monitor products have been assessed
to IEC 61508 and are in compliance with this standard’s SIL 2
requirements. SIL (Safety Integrity Level) compliance is increasing-
ly required on general industry gas monitoring products. These
MSA products meet stringent SIL 2 compliance safety specifica-
tion requirements. SIL2 Safety Manuals are available from MSA
upon customer request. — MSA, 800/672-2222,
www.MSAnet.com
manual systems to fully instrumented PLC-based units with an unlimited vari-
ety of inputs and outputs. Standard units are available to provide activated
Circle 140 on Card
polymer solution from 30 gph through 21,000 gph. — Fluid Dynamics Inc.,
215/699-8700
Self Cleaning Water Filters
Circle 143 on Card
The TEKLEEN® self cleaning water filters can save money that is
spent every day cleaning and replacing screens, bags and car-
tridges. The filters range from 1-36” in pipe size and are completely
maintenance free. They feature High end all stainless steel fabrica-
tion at carbon steel prices. Ideal for cooling towers, chillers, con-
densers, waste water, spray nozzle protection and drinking water
Submersible Pressure Transducers
The CS450 and CS455 transducers measure pressure with a stat-
ic accuracy within ±0.1% Fs over a 0°Cto 60°C temperature
range. The CS450 /CS455 can output either an SDI- 12 or RS-232
signal interface to manufacturer’s dataloggers or other record-
ing devices. Both sensors are available with six pressure range
options, from 0-2.9 psig (0-20 kPa) up to 0-145 psig (0-1000 kPa). A piezoresistive sensor is
housed in a metal case. The Hytrel cable can compensate for atmospheric pressure fluc-
tuations. — Campbell Scientific Inc., 435/753-2342
application. — Automatic Filters Inc., 800/336-1942
Circle 139 on Card
®
Circle 144 on Card
Level Transmitter for Wastewater
The Model 675 submersible level transmitter is designed
for slurries and highly viscous environments where clog-
ging of the sensor is possible. A 3.5-
inch flush diaphragm within a stain-
less steel shark cage prevents
unwanted clogging of the sensor
area. The device is able to perform in
depths up to 138 feet of water and is
approved for intrinsically safe opera-
tion in hazardous locations as designated by Class 1,
Div 1, Groups A, B, C & D and Class II, Groups E, F & G
when used with approved barrier. — AMETEK PMT
Products, 215/355-6900 Circle 145 on Card
Sampling Pump Service
This repair center specializes
in repairing most brands of
air samplers and also sells
refurbished air samplers.
They repair and sell both
personal samplers and high
volume samplers. Also battery packs are rebuilt and
chargers are repaired. All services are warranted and
the turnaround time is usually one to two weeks.. —
Atlanta Lab Systems LLc., 770/993-7850,
www.atlantalab.com